Back to Search
Start Over
Ion pairing based polyurethane foam sorbent packed column combined with inductively coupled plasma–optical emission spectrometry for sensitive determination and chemical speciation of bismuth(III & V) in water
- Source :
- Journal of Industrial and Engineering Chemistry. 28:377-383
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- The sorption profile of trace concentrations of bismuth(III) species from aqueous KI–H 2 SO 4 media onto the ion pairing procaine hydrochloride (PQ + .Cl − ) based polyurethane foam (PUFs) was studied. A dual–mode of bismuth(III) sorption as a ternary complex ion associate [PQ + .BiI 4 − ] involving absorption due to a “weak base anion exchanger” and an added component for “surface adsorption” seems the proposed mechanism for bismuth(III) retention. The capacity of bismuth(III) sorption was found equal 40.05 ± 1.10 mg g −1 . Complete separation of spiked bismuth(III) at various concentrations (5–15 μg mL −1 ) from water onto the proposed sorbent packed columns at 5 mL min −1 flow rate was successfully achieved. The retained bismuth(III) species were recovered quantitatively from the sorbent packed columns (98.4 ± 2.4%, n = 5) with HNO 3 (1.0 mol L −1 ). Bismuth(V) after reduction to Bi(III) was also preconcentrated, recovered from the sorbent packed column and subsequently analyzed by inductively coupled plasma–optical emission spectrometry (ICP–OES). The height equivalent to the theoretical plates (HETP), number of plates (N), critical and breakthrough capacities of sorbent packed column towards bismuth(III) retention were evaluated. Based on these results, a simple and sensitive PQ + .Cl − –PUF packed column was developed for determination and speciation of trace concentrations of bismuth(III & V) species in water by ICP–OES. The limits of detection (LOD) and quantification (LOQ) of Bi(III) were found 0.09 and 0.30 μg L −1 , respectively. The relative standard deviation (RSD) for 5 replicates of 50 ng L −1 Bi at 2.0 mL min −1 flow was ±3.7%. The proposed column was validated and applied for the preconcentration, separation and subsequent determination of analyte in Environmental water reference material (TMDW) and water samples. The results were found to be in good agreement with the CRM at the 95% confidence level.
Details
- ISSN :
- 1226086X
- Volume :
- 28
- Database :
- OpenAIRE
- Journal :
- Journal of Industrial and Engineering Chemistry
- Accession number :
- edsair.doi...........80f5f8b4737e3d59dda0f2047ab4a481
- Full Text :
- https://doi.org/10.1016/j.jiec.2015.02.024