Superheated superconducting granule detectors for dark matter
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 344:239-242
- Publication Year :
- 1994
- Publisher :
- Elsevier BV, 1994.
-
Abstract
- The response of Superheated Superconducting Granule (SSG) devices to nuclear recoils has been explored by irradiating SSG detectors with a 70Me$\!$V neutron beam. In the past we have tested Al SSG and more recently, measurements have been performed with Sn and Zn detectors. The aim of the experiments was to test the sensitivity of SSG detectors to recoil energies down to a few ke$\!$V. In this paper, the preliminary results of the neutron irradiation of a SSG detector made of Sn granules 15-20$\mu$m in diameter will be discussed. For the first time, recoil energy thresholds of $\sim$1ke$\!$V have been measured.
Details
- ISSN :
- 01689002
- Volume :
- 344
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :