Back to Search Start Over

Divertor Langmuir Probe Measurements in JET

Authors :
J. Lingertat
K. Günther
R. D. Monk
H. Y. Guo
S. Clement
C. F. Maggi
A. Tabasso
G. F. Matthews
M. Stamp
P.D. Morgan
S. J. Davies
A. V. Chankin
A. Loarte
Source :
Contributions to Plasma Physics. 36:37-44
Publication Year :
1996
Publisher :
Wiley, 1996.

Abstract

In this paper, results from the array of fixed Langmuir probes in the JET Mark I divertor are presented. During low density discharges there is good agreement between single and triple probes. At higher density, near the onset of divertor detachment, very low values of the electron to ion saturation current (even < 1) are observed which results in an overestimation of the electron temperature, particularly by the triple probe. Alternative methods of probe interpretation are applied and comparisons carried out with independent measurements. The consistency of probe measurements during H-mode discharges are also briefly discussed.

Details

ISSN :
08631042
Volume :
36
Database :
OpenAIRE
Journal :
Contributions to Plasma Physics
Accession number :
edsair.doi...........7d980b96827f156f76d87d91100789ab
Full Text :
https://doi.org/10.1002/ctpp.19960360107