Back to Search Start Over

Diagnostic accuracy of left ventricular diastolic transverse strain imaging by speckle tracking echocardiography for diagnosing chest pain in diabetic patients

Authors :
Atsushi Tanaka
Hiroshi Ito
Yoshihiro Seo
Junichi Yoshikawa
E Hyodo
Katsuhisa Ishii
Hirotoshi Watanabe
Takashi Akasaka
H Kihara
Yusuke Yoshikawa
Tomoko Ishizu
Masao Daimon
Source :
European Heart Journal. 41
Publication Year :
2020
Publisher :
Oxford University Press (OUP), 2020.

Abstract

Background Two-dimensional speckle tracking echocardiography (2D-STE) has been reported to be useful for the diagnosis of myocardial ischemia by detecting delayed relaxation (diastolic stunning) after an episode of angina. 2D-longitudinal strain is not specific besides ischemia such as diastolic dysfunction, and diabetes have been associated with abnormal longitudinal fibers. The aim is to evaluate the diagnostic accuracy of Left ventricular (LV) diastolic transverse strain imaging by STE to detect the presence of acute coronary syndrome (ACS) in diabetic patients with acute chest pain. Methods 385 consecutive patients with acute chest pain and without wall motion abnormality, who were admitted to an emergency department (ED) at 1 of 12 clinical sites in Japan, were enrolled and underwent 2D-STE at ED. Left ventricular (LV) transverse strain values at aortic valve closure (A) and one-third of diastole duration (B) were measured. The strain imaging diastolic index (SI-DI) was value was determined as: (A − B)/A × 100% to assess the LV diastolic strain imaging and was used to identify the regional LV delayed relaxation. All patients underwent coronary CT or coronary angiography to establish the diagnosis of ACS. Clinicians were blinded to the 2D-STE results. Results Out of 385 patients, 2D-STE analysis was possible in 365 patients (94%). 76 patients were diabetic (DM+), and 289 patients were non-diabetic (DM-). With assessment of coronary CT or coronary angiography, ACS was diagnosed in 125 patients (34%). 2D-STE was obtained at a mean of 5.3 hours after chest pain episode. Transverse SI-DI of ischemic segments were significantly lower than those of non-ischemic segments (p value Conclusion LV diastolic transverse strain imaging by 2D-STE at ED increase the sensitivity, specificity and accuracy to predict the presence of ACS in diabetic patients with chest pain, as well as non-diabetic patients. (UMIN000013859). Figure 1. Transverse Strain (SI-DI): AUC (95% CI) Funding Acknowledgement Type of funding source: None

Details

ISSN :
15229645 and 0195668X
Volume :
41
Database :
OpenAIRE
Journal :
European Heart Journal
Accession number :