Back to Search Start Over

Characteristics of Hot-dip Zinc Coating Measurement

Authors :
G. Bikulcius
A. Rucinskiene
E. Matulionis
Source :
Transactions of the IMF. 81:73-74
Publication Year :
2003
Publisher :
Informa UK Limited, 2003.

Abstract

After performing comparative coating thickness measurements using magnetic. coulometric and profilographic methods it has been determined that the coating thickness value obtained by the magnetic method is lower than the actual value, measured by the profilographic method. The measurements of hot-dip coatings with a thickness of 15-20 μm using a magnetic coating thickness gauge have shown that the measurement error may reach 32 %. An introduction of a correction factor equal to 1.3 was proposed.

Details

ISSN :
17459192 and 00202967
Volume :
81
Database :
OpenAIRE
Journal :
Transactions of the IMF
Accession number :
edsair.doi...........77e84bd16209b88a4476dba9b5e4c7c1
Full Text :
https://doi.org/10.1080/00202967.2003.11871493