Abstract

A large etching system has been developed for the plastic track detector CR-39. The main components are two large etching baths, each with a volume of 9 m 3 . In spite of such a large volume, their effective heat-insulation and efficient stirring enables us to carry out large scale and uniform etching of CR-39. Using this system, 80 m 2 of CR-39 plates can be etched at one time.