Conditioning and optimization of discharges in ASDEX
- Source :
- Journal of Nuclear Materials. :286-290
- Publication Year :
- 1980
- Publisher :
- Elsevier BV, 1980.
-
Abstract
- In the first experimental phase the divertor tokamak ASDEX was run with a closed SS-limiter. The cleaning procedure for the vessel consisted of baking to 120°C, carbon removal by glow discharge in hydrogen, and oxygen removal with a continuous low power 50 Hz AC discharge. Wall contact of the plasma was reduced by carefully positioning the plasma with a feedback system. Discharges with plasma currents up to 280 kA and a disruption-free duration of up to 1 s were reliably produced with a filling pressure of 5 × 10 −5 mbar and a programmed current rise. No change in start-up conditions and discharge behaviour was observed in material limiter discharges with superimposed divertor field.