A Study of Bolt Conclusion Evaluation for Ultrasonic Waves Using Scattering Parameter

Authors :
Kazuhiko Imano
Motoyuki Takahashi
Makoto Fukuda
Source :
Proceedings of The 2nd International Conference on Intelligent Systems and Image Processing 2014.
Publication Year :
2014
Publisher :
The Institute of Industrial Applications Engineers, 2014.

Abstract

The evaluation method of the bolt conclusion for ultrasonic waves using reflection coefficient S 11 of scattering parameter was proposed. Ultrasonic waves of 2 MHz were used because variation of reflection coefficient S 11 was the greatest. Reflection coefficient S 11 was decreased as the axial force was increased. Usefulness of the evaluation method of the bolt conclusion using reflection coefficient S 11 was demonstrated.

Details

Database :
OpenAIRE
Journal :
Proceedings of The 2nd International Conference on Intelligent Systems and Image Processing 2014
Accession number :
edsair.doi...........67fb6245bb221c9583e95d2f89989223
Full Text :
https://doi.org/10.12792/icisip2014.012