Stability Analysis and Fabrication Process of a Multiple Flow Focusing Microdevice Built in SU-8
- Source :
- 2007 IEEE International Symposium on Industrial Electronics.
- Publication Year :
- 2007
- Publisher :
- IEEE, 2007.
-
Abstract
- In this paper, the design and fabrication process of a three-dimensional and multiple flow focusing device, intended for low-cost mass production of liquid-liquid emulsions, are reported. The material used to build the device is the SU-8 epoxy photoresist because of its adequate properties for flow focusing technology. At first, the behavior of the device is unstable because of interaction between neighboring devices, which produces a undesirable operation. This behavior is simulated and analyzed, and a solution to solve this instability is chosen from these simulations. From the simulations, a graphical representation of stable and unstable behaviors as a function of flow rates of both fluids is obtained. Finally, the new design that solves the instabilities is simulated and its fabrication process is reported. A stable, multiple three-dimensional flow focusing device is achieved with the chosen solution.
Details
- Database :
- OpenAIRE
- Journal :
- 2007 IEEE International Symposium on Industrial Electronics
- Accession number :
- edsair.doi...........67840f12103b887ab5428548cd68d21c
- Full Text :
- https://doi.org/10.1109/isie.2007.4375134