Zero boil-off methods for large-scale liquid hydrogen tanks using integrated refrigeration and storage

Authors :
K M Jumper
Adam Swanger
James E. Fesmire
Wesley L. Johnson
Thomas M. Tomsik
William Notardonato
Source :
IOP Conference Series: Materials Science and Engineering. 278:012012
Publication Year :
2017
Publisher :
IOP Publishing, 2017.

Abstract

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multilayer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

Details

ISSN :
1757899X and 17578981
Volume :
278
Database :
OpenAIRE
Journal :
IOP Conference Series: Materials Science and Engineering
Accession number :
edsair.doi...........6473f6bd4c383d5980ea8e719622e0a5
Full Text :
https://doi.org/10.1088/1757-899x/278/1/012012