AC Loss and Other Researches with 5 m HTS Model Cables

Authors :
Sergey S. Fetisov
K. A. Shutov
A.A. Nosov
Vitaly S. Vysotsky
Source :
IEEE Transactions on Applied Superconductivity. 21:1001-1004
Publication Year :
2011
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2011.

Abstract

The test facility developed in Russian Scientific R&D Cable Institute permits to perform extensive tests of heavily instrumented HTS cable models with length up to 5 m. Several HTS cables with different design have been developed and tested at this facility. The test programs included, besides usual critical current measurements, current distribution measurements among layers, joint resistance test, etc. The facility's equipment permits digital measurements of voltage and current with high accuracy and, therefore, digital ac loss analysis in model cables. In this paper we present the details of the test facility and results of tests and ac loss measurements in few 5 m model cables. ac losses in model cables made of 1 G and 2 G wires and other cable parameters are discussed and compared.

Details

ISSN :
15582515 and 10518223
Volume :
21
Database :
OpenAIRE
Journal :
IEEE Transactions on Applied Superconductivity
Accession number :
edsair.doi...........644910c5912faa34baa1aaf3a8234178
Full Text :