Back to Search Start Over

The correlation radiometer- A new application in MM-wave total power radiometry

Authors :
Todd Gaier
Alan Tanner
Boon Lim
Pekka Kangaslahti
Source :
IGARSS
Publication Year :
2013
Publisher :
IEEE, 2013.

Abstract

We describe the design and performance of a 180 GHz correlation radiometer suitable for remote sensing. The radiometer provides continuous comparisons between a the observed signal and a reference load to provide stable radiometric baselines. The radiometer was assembled and tested using parts from the GeoSTAR-II instrument and is fully compatible with operation in a synthetic aperture radiometer or as a standalone technology for use in microwave sounding and imaging . This new radiometer was tested over several days easily demonstrating the required 6 hour stability requirement for observations of mean brightness temperature for a geostationary instrument.

Details

Database :
OpenAIRE
Journal :
2013 IEEE International Geoscience and Remote Sensing Symposium - IGARSS
Accession number :
edsair.doi...........643d246475b36613f85ad5226aee2e90