Uranium gas sampling calorimeter

Authors :
I. Vorobiev
Yu. Galaktionov
Vitaliy G. Shevchenko
A. Kunin
A. Arefiev
V. Morgunov
Yu. Gorodkov
V. Pojidaev
E. Tarkovski
M. Kosov
V. Shoutko
A. Gordeev
V. Plyaskin
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 245:71-77
Publication Year :
1986
Publisher :
Elsevier BV, 1986.

Abstract

A gas sampling calorimeter with uranium absorbers was built and tested in a beam of pions and electrons of 1 to 6 GeV/ c . As far as the detection of electromagnetic showers is concerned, no difference between uranium and a conventional absorber is found. The energy dependence of the resolution of the calorimeter for hadrons is given for 4.5 and 9 mm sampling. The measured π e ratio is 0.83±0.03.