Back to Search Start Over

Development of CAD scheme for automated detection of intracranial aneurysms in magnetic resonance angiography

Authors :
Shigehiko Katsuragawa
Toshinori Hirai
Ryuji Ikeda
Yasuyuki Yamashita
Hiroyuki Abe
Hidetaka Arimura
Qiang Li
Kunio Doi
Yukunori Korogi
Source :
CARS
Publication Year :
2004
Publisher :
Elsevier BV, 2004.

Abstract

We have developed a computer-aided diagnostic (CAD) scheme for automated detection of intracranial aneurysms in magnetic resonance angiography (MRA). A total of 29 cases with 36 aneurysms and 31 non-aneurysm cases were processed by use of the selective enhancement filter for dots (aneurysms). All candidates were classified into four types according to the size and local structures based on the effective diameter and the skeleton image of each candidate. A number of false positives were removed in each group by use of rule-based schemes and linear discriminant analysis. All of 36 aneurysms were correctly detected with 0.55 false positives per patient. The CAD scheme would be useful in assisting radiologists for detection of intracranial aneurysms in MRA.