Back to Search Start Over

Development of an implantable collamer lens sizing model: a retrospective study using ANTERION swept-source optical coherence tomography and a literature review

Authors :
Taein Kim
Su Jeong Kim
Bo Young Lee
Hye Jin Cho
Beom Gi Sa
Ik Hee Ryu
Jin Kuk Kim
In Sik Lee
Eoksoo Han
Hyungsu Kim
Tae Keun Yoo
Source :
BMC Ophthalmology. 23
Publication Year :
2023
Publisher :
Springer Science and Business Media LLC, 2023.

Abstract

Background Optimal sizing for phakic intraocular lens (EVO-ICL with KS-AquaPort) implantation plays an important role in preventing postoperative complications. We aimed to formulate optimal lens sizing using ocular biometric parameters measured with a Heidelberg anterior segment optical coherence tomography (AS-OCT) device. Methods We retrospectively analyzed 892 eyes of 471 healthy subjects treated with an intraocular collamer lens (ICL) and assigned them to either the development (80%) or validation (20%) set. We built vault prediction models using the development set via classic linear regression methods as well as partial least squares and least absolute shrinkage and selection operator (LASSO) regression techniques. We evaluated prediction abilities based on the Bayesian information criterion (BIC) to select the best prediction model. The performance was measured using Pearson’s correlation coefficient and the mean squared error (MAE) between the achieved and predicted results. Results Measurements of aqueous depth (AQD), anterior chamber volume, anterior chamber angle (ACA) distance, spur-to-spur distance, crystalline lens thickness (LT), and white-to-white distance from ANTERION were highly associated with the ICL vault. The LASSO model using the AQD, ACA distance, and LT showed the best BIC results for postoperative ICL vault prediction. In the validation dataset, the LASSO model showed the strongest correlation (r = 0.582, P Conclusion This is the first study to develop a postoperative ICL vault prediction and lens-sizing model based on the ANTERION. As the measurements from ANTERION and other AS-OCT devices are not interchangeable, ANTERION may be used for optimal ICL sizing using our formula. Because our model was developed based on the East Asian population, further studies are needed to explore the role of this prediction model in different populations.

Subjects

Subjects :
Ophthalmology
General Medicine

Details

ISSN :
14712415
Volume :
23
Database :
OpenAIRE
Journal :
BMC Ophthalmology
Accession number :
edsair.doi...........599eb93a491e43af7aac5e350083ac69
Full Text :
https://doi.org/10.1186/s12886-023-02814-7