Back to Search Start Over

Erratum to: Mobile source of high-energy single-cycle terahertz pulses

Erratum to: Mobile source of high-energy single-cycle terahertz pulses

Authors :
Jérôme Kasparian
Yannick Petit
Andrei Stepanov
Jean-Pierre Wolf
Luigi Bonacina
Stefano Henin
Source :
Applied Physics B. 115:293-293
Publication Year :
2014
Publisher :
Springer Science and Business Media LLC, 2014.

Abstract

In 2010, we reported [1] on a demonstration of a mobile source of high-energy near-single-cycle THz pulses based on a tilted pulse front optical rectification set-up, pumped by a mobile terawatt laser (Teramobile). The absolute value of the THz pulse energy was measured with a pyroelectric detector (Coherent Molectron J4-05). The company does not provide a spectral sensitivity dependence for this detector below 3.3 THz. In the reported experiments, generated THz pulses had broad spectra centred at 0.2 THz [1]. Previously, this detector was used for measuring the energy of near-single-cycle THz pulses with an average frequency of 0.9 THz generated by an accelerator-based source [2]. Afterwards, it was reported that the sensitivity of the Coherent pyroelectric detector at 1 THz was approximately 1.8 times less than the specified sensitivity at 1.06 lm [3], and this difference has been take into account in a following publication [7]. Recently, we compared the sensitivity of the Coherent Molectron J4-05 detector with that of another widely used pyroelectric THz detector (Microtech Instruments) [3–6]. The latter detector is provided with a calibration curve of the spectral dependence of the sensitivity in the frequency range of 0.12–3 THz. As a result, we found that at frequencies of 0.2–0.5 THz, the Coherent Molectron J4-05 detector underestimates the THz pulse energy by a factor of about 3.5 with regard to the Microtech Instruments detector. This finding evidences an additional drop of the Coherent Molectron J4-05 detector sensitivity for THz wave frequencies below 1 THz. By this comparison, we conclude that the THz pulse energy in Ref. [1] should significantly be re-estimated, up to 175 lJ (instead of the initially published value of 50 lJ), which is to the best of our knowledge the highest energy of near-single-cycle THz pulses generated by tabletop sources.

Details

ISSN :
14320649 and 09462171
Volume :
115
Database :
OpenAIRE
Journal :
Applied Physics B
Accession number :
edsair.doi...........595c230e0a5b9c7a813ff362ff580690
Full Text :
https://doi.org/10.1007/s00340-013-5619-7