Heat transport characteristics of the capillary pumped loop for cooling the tower-type computer -2nd report: considering the inclination of the evaporator
- Source :
- Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006..
- Publication Year :
- 2006
- Publisher :
- IEEE, 2006.
-
Abstract
- The capillary pumped loop has been widely investigated for a space thermal control device. This cooling device with high reliability and thermal controllability is considered to be suited to cool the electronic device like a tower-type personal computer, because the capillary pumped loop is good for absorbing heat from high heat flux region like a CPU, transporting it and releasing it from the large surface area like a packaging of the tower-type computer. In this study the capillary pumped loop was manufactured as a cooling device for the tower-type personal computer, and the heat transport characteristics was investigated. The experimental equipment consisted of the evaporator, the condenser, the liquid path and the vapor path. The heat transport length was set to 2500mm considering the air-cooled heat release area of the condenser. In the 1st report the effect of the wick dimension, cooling water temperature, evaporator height above the condenser were investigated. In this study, the influence of the inclination of the evaporator on the heat transport characteristics was mainly investigated. In results, this capillary pumped loop was able to work within the inclined angle of 20deg, but the maximum heat transport rate decreased as the inclination increased
Details
- Database :
- OpenAIRE
- Journal :
- Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006.
- Accession number :
- edsair.doi...........5798fdbb709078e2b0b5faa2355799c7
- Full Text :
- https://doi.org/10.1109/itherm.2006.1645395