Back to Search
Start Over
The Cryogenic Space Charge Measurement Using Pulsed Electro-Acoustic Method
- Source :
- IEEE Transactions on Dielectrics and Electrical Insulation. 28:1088-1091
- Publication Year :
- 2021
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2021.
-
Abstract
- In this report, a pulsed electro-acoustic (PEA) device is modified to test the charge profile in epoxy resin at 77 K (-196°C) and successfully obtains the charge signal. A piezoelectric material suitable for cryogenic application is chosen for the measurement. In the experiment, the polarization and depolarization tests are operated with different voltage supply procedures. After initial wave recovery, the waveforms are discernable enough to identify the charge information. It is found that the charges are much less active at the low temperature with both slow dissipating rate and low injection quantity, comparing to the case at 293 K.
Details
- ISSN :
- 15584135 and 10709878
- Volume :
- 28
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Dielectrics and Electrical Insulation
- Accession number :