Back to Search Start Over

Impact of imaging approach on radiation dose and associated cancer risk in children undergoing cardiac catheterization

Authors :
Chu Wang
Terry K. Yoshizumi
Gregory A. Fleming
Kevin D. Hill
Andrew J. Einstein
Natalie Januzis
Jennifer S. Li
Giao Nguyen
Source :
Catheterization and Cardiovascular Interventions. 89:888-897
Publication Year :
2016
Publisher :
Wiley, 2016.

Abstract

Objectives To quantify the impact of image optimization on absorbed radiation dose and associated risk in children undergoing cardiac catheterization. Background Various imaging and fluoroscopy system technical parameters including camera magnification, source-to-image distance, collimation, antiscatter grids, beam quality, and pulse rates, all affect radiation dose but have not been well studied in younger children. Methods We used anthropomorphic phantoms (ages: newborn and 5 years old) to measure surface radiation exposure from various imaging approaches and estimated absorbed organ doses and effective doses (ED) using Monte Carlo simulations. Models developed in the National Academies' Biological Effects of Ionizing Radiation VII report were used to compare an imaging protocol optimized for dose reduction versus suboptimal imaging (+20 cm source-to-image-distance, +1 magnification setting, no collimation) on lifetime attributable risk (LAR) of cancer. Results For the newborn and 5-year-old phantoms, respectively ED changes were as follows: +157% and +232% for an increase from 6-inch to 10-inch camera magnification; +61% and +59% for a 20 cm increase in source-to-image-distance; −42% and −48% with addition of 1-inch periphery collimation; −31% and −46% with removal of the antiscatter grid. Compared with an optimized protocol, suboptimal imaging increased ED by 2.75-fold (newborn) and fourfold (5 years old). Estimated cancer LAR from 30-min of posteroanterior fluoroscopy using optimized versus suboptimal imaging, respectively was 0.42% versus 1.23% (newborn female), 0.20% versus 0.53% (newborn male), 0.47% versus 1.70% (5-year-old female) and 0.16% versus 0.69% (5-year-old male). Conclusions Radiation-related risks to children undergoing cardiac catheterization can be substantial but are markedly reduced with an optimized imaging approach. © 2016 Wiley Periodicals, Inc.

Details

ISSN :
15221946
Volume :
89
Database :
OpenAIRE
Journal :
Catheterization and Cardiovascular Interventions
Accession number :
edsair.doi...........4fa7558dfacbc2284be745058f533e18
Full Text :
https://doi.org/10.1002/ccd.26630