The Shielding Effect of Low Resistivity Layer in TEM
- Source :
- Technology and Application of Environmental and Engineering Geophysics ISBN: 9789811032431
- Publication Year :
- 2017
- Publisher :
- Springer Singapore, 2017.
-
Abstract
- Transient electromagnetic method can penetrate high-resistivity shielding layer and delineate underlying strata or structure. However, the shielding effects of low-resistivity layer on transient electromagnetic exploration are often ignored, especially for low-resistive overburden. It is of great importance to ensure exploration depth and improve detection precision by researching the relationship between low-resistive layer and electromagnetic field. In this paper, the propagation process of the subsurface and surface TEM field responses were simulated using finite-difference time-domain method (FDTD). And the characteristic response of low-resistivity overburden was studied using numerical modeling. The observation time with low-resistivity layer was estimated using observation time formula. It was shown that a low-resistivity layer will not only reduce the propagation speed of the field, but also weaken the response of low-resistivity target.
Details
- ISBN :
- 978-981-10-3243-1
- ISBNs :
- 9789811032431
- Database :
- OpenAIRE
- Journal :
- Technology and Application of Environmental and Engineering Geophysics ISBN: 9789811032431
- Accession number :
- edsair.doi...........4cc89750770c31ad7c1698f4b4c29d7b
- Full Text :
- https://doi.org/10.1007/978-981-10-3244-8_18