Back to Search Start Over

Tracking Studies on the Effects of Magnet Multipoles on the Aperture of the RHIC Heavy Ion Collider

Authors :
G. Parzen
G. F. Dell
Source :
IEEE Transactions on Nuclear Science. 32:1620-1622
Publication Year :
1985
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 1985.

Abstract

Tracking studies including the effects of random multipoles resulting from construction errors have been made for RHIC with two independent tracking programs at three different tunes. The studies were made using ten different sets of random errors for each of the programs. The aperture was defined as the worst case, and the results of the two programs are in good agreement. A second set of studies was made for which the number of dipoles was doubled to determine whether doubling the number of independent random errors results in a reduction of the effects or random multipoles. The results for the two cases, one dipole per half cell and two dipoles per half cell, indicate there is little difference in dynamic aperture.

Details

ISSN :
00189499
Volume :
32
Database :
OpenAIRE
Journal :
IEEE Transactions on Nuclear Science
Accession number :
edsair.doi...........4b2168946616cf9e93791768374228c3
Full Text :
https://doi.org/10.1109/tns.1985.4333670