Abstract
- Objective To assess intraobserver and interobserver variability in ovarian volume and gray-scale and color flow index measurements using transvaginal, three-dimensional, power Doppler ultrasonography. Methods Eleven women (22 ovaries) were examined on day 8 of controlled ovarian hyperstimulation therapy, which was part of their in vitro fertilization treatment protocol. The patients were examined twice by the first observer and once by the second observer. The acquired volume datasets were analyzed using the VOCAL(TM) imaging program, enabling the assessment of ovarian volume, vascularization index (VI), flow index (FI), vascularization flow index (VFI) and mean grayness (MG). For these parameters the intraclass (intra-CC) and interclass (inter-CC) correlation coefficients, within-observer and between-observers repeatability coefficient (r) and limits of agreement were calculated. Results Both intraobserver and interobserver repeatability of ovarian volume measurements were considered very good with an intra-CC value of 1.00 and inter-CC value of 0.99, respectively. Also VI, FI, VFI and MG measurements were repeatable by a single observer, the intra-CC ranging from 0.82 to 0.91. The interobserver reproducibility was also good for VI, VFI and MG measurements (inter-CC values 0.73, 0.70 and 0.81, respectively), but for FI measurements the reproducibility was poor (inter-CC = 0.29, r = 7.87). Conclusions In general, the intraobserver reproducibility was better than interobserver reproducibility for all parameters. The volume assessments were reproducible both by one observer and by two separate observers. The intraobserver and interobserver variabilities were acceptable for VI, VFI and MG, whereas for FI the interobserver reproducibility was poor. Our results suggest that measurement of gray-scale and color Doppler flow indices is reproducible thus allowing them to be used in clinical practice and research. (Less)
- Subjects :
- Reproducibility
medicine.medical_specialty
Radiological and Ultrasound Technology
business.industry
Obstetrics and Gynecology
General Medicine
Repeatability
Controlled ovarian hyperstimulation
Grayscale
Surgery
symbols.namesake
Power doppler
Reproductive Medicine
medicine
symbols
Radiology, Nuclear Medicine and imaging
Color flow
Ultrasonography
business
Nuclear medicine
Doppler effect
Subjects
Details
- ISSN :
- 09607692
- Volume :
- 21
- Database :
- OpenAIRE
- Journal :
- Ultrasound in Obstetrics and Gynecology
- Accession number :
- edsair.doi...........49524f99700fe14dd20b79e3d32bfa98
- Full Text :
- https://doi.org/10.1002/uog.62