Radiation effects on the proportional counter X-ray detectors on board the NEAR spacecraft

Authors :
S. R. Floyd
R. D. Starr
H.W Leidecker
John O. Goldsten
Pamela Elizabeth Clark
Jacob I. Trombka
David R. Roth
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 422:577-581
Publication Year :
1999
Publisher :
Elsevier BV, 1999.

Abstract

The X-ray proportional counters on board the Near Earth Asteroid Rendezvous (NEAR) spacecraft have exhibited a resolution degradation and recovery phenomenon several times during the long cruise phase of the mission. The resolution is checked periodically by commanding an 55 Fe source into the window area. The degradation is seen as a low energy tailing of the 5.9 keV photopeak. Two events have occurred which provided good spectral data for better understanding the degradation phenomenon. In November 1997 a large solar particle event occurred that degraded the resolution and excited copper in the collimator. Eventually the detectors returned to normal. In January 1998 the spacecraft performed an Earth swingby gravity assist maneuver. The near Earth environment excited the magnesium and aluminum in the filter elements. The copper line was also produced. The NEAR spacecraft was launched in February 1996 and will rendezvous and orbit the asteroid 433 Eros in early 1999.

Details

ISSN :
01689002
Volume :
422
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi...........47ddb4530576b276ba6f293d77f51827
Full Text :
https://doi.org/10.1016/s0168-9002(98)00940-1