Evaluation of four monoclonal antibodies against HLA-B27 for their reliability in HLA-B27 typing with flow cytometry (FC): Comparison with the classic microlymphocytotoxic test (MLCT)
- Source :
- Cytometry. 26:209-215
- Publication Year :
- 1996
- Publisher :
- Wiley, 1996.
-
Abstract
- Typing for HLA-B27 by serological methods is routinely performed using the microlymphocytotoxic test (MLCT). Since monoclonal antibodies (MAB) against HLA-B27 are available, flow cytometry (FC), which requires less time than the MLCT has been developed as an alternative technique. The aim of the present study was to check the accuracy and reliability of this method using different MAB against HLA-B27 in comparison to MLCT (using polyclonal antibodies against HLA-B27 and cross-reacting specificities [CRS]). FC was performed in 144 patients with HLA-B27-related rheumatic disorders (seronegative spondarthritides) using a special software package which requires corresponding calibration beads in order to achieve a standardized setup of the flow cytometer. MAB from the following producers were used: Becton & Dickinson (BD), Behringwerke (BE), One Lambda (OL), and Immunotech (IT). In addition to the critical limit of fluorescence intensity (FI) which indicates positivity if exceeded, provided by the software (but valid only for the MAB from BD), empirically twice the value of the STD calculated from the mean of the FI values of HLA-B27 positive patients was regarded a good cut off for the HLA-B27 positivity in FC measurements with the MAB used. Using a standard protocol including an incubation of whole EDTA-anticoagulated blood for 15 min with MAB against HLA-B27 (FITC-conjugated) and CD3 (PE-conjugated) and a lysis of erythrocytes, good discrimination between HLA-B27 positive and negative patients was obtained. Cross reactions with HLA-B27 positive patients occurred except when the MAB from OL was used. One false-negative result was found with OL's MAB (out of 22) and false-positive results occurred in HLA-B7+ patients when MAB from BD, BE, and IT were used. Unfortunately also 1 false-positive result (out of 57) was obtained in HLA-B7−, B27− patients with IT's MAB. Errors in the interpretation of the FC analysis might be avoided if more than one MAB (including those not cross reacting with HLA-B7) are used. © 1996 Wiley-Liss, Inc.
- Subjects :
- musculoskeletal diseases
HLA-B27
medicine.diagnostic_test
biology
medicine.drug_class
Chemistry
HLA-B27 typing
Biophysics
Cell Biology
Hematology
Monoclonal antibody
Molecular biology
Pathology and Forensic Medicine
Flow cytometry
Serology
Fluorescence intensity
Endocrinology
Polyclonal antibodies
Immunology
medicine
biology.protein
Typing
Subjects
Details
- ISSN :
- 10970320 and 01964763
- Volume :
- 26
- Database :
- OpenAIRE
- Journal :
- Cytometry
- Accession number :
- edsair.doi...........456396596a1b04b72f4a53a0a5698c7f
- Full Text :
- https://doi.org/10.1002/(sici)1097-0320(19960915)26:3<209::aid-cyto5>3.0.co;2-9