Back to Search Start Over

Performance analysis for the modified excitation system of synchronous machine connected to HVDC system

Authors :
Byung-Mo Yang
Bong-Eon Kho
Chan-Ki Kim
Gil-Jo Jeong
Source :
IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02.
Publication Year :
2003
Publisher :
IEEE, 2003.

Abstract

This paper analyses the transient performance of the modified excitation system using 4-quadrant chopper for a synchronous machine connected to HVDC system. Conventionally, capacitors are used to supply reactive power requirement at a strong converter bus. And the installation of a synchronous machine is essential in an isolated weak network to re-start after a shutdown of HVDC and to increase the system strength. However, a conventional static excitation system has some problems which are harmonic instability and the system stress due to overvoltage. To reduce these problems, the new excitation system, which has 4-quadrant chopper, is proposed. As the proposed system provides the capability to allow reverse current and isolate between AC network and excitation power, problems of overvoltage and harmonic instability can be solved. The investigation is performed and confirmed by the time domain digital simulation using PSCAD/EMTDC program.

Details

Database :
OpenAIRE
Journal :
IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02
Accession number :
edsair.doi...........45211eb503d84bc5fab2a400283702fc
Full Text :
https://doi.org/10.1109/iecon.2002.1187613