Back to Search Start Over

High temperature corrosion evaluation and lifetime prediction of porous Fe22Cr stainless steel in air in temperature range 700–900 °C

Authors :
Damian Koszelow
M. Makowska
Piotr Jasiński
Jakub Karczewski
Sebastian Molin
F. Marone
Source :
Corrosion Science. 189:109589
Publication Year :
2021
Publisher :
Elsevier BV, 2021.

Abstract

This work describes a high temperature corrosion kinetics study of ~30% porous Fe22Cr alloys. The surface area of the alloy (~0.02 m2 g-1) has been determined by tomographic microscopy. The weight gain of the alloys was studied by isothermal thermogravimetry in the air for 100 hours at 700 - 900 °C. Breakaway oxidation was observed after oxidation at 850 °C (~100 hours) and 900 °C (~30 hours). The lifetime prediction shows the investigated porous alloy can be used for >3000 hours at temperatures

Details

ISSN :
0010938X
Volume :
189
Database :
OpenAIRE
Journal :
Corrosion Science
Accession number :
edsair.doi...........441fb999f67f34e86324e56738f02b60