Back to Search
Start Over
Studying the counting rate capability of a glass multigap resistive plate chamber at an increased operating temperature
- Source :
- Instruments and Experimental Techniques. 56:265-270
- Publication Year :
- 2013
- Publisher :
- Pleiades Publishing Ltd, 2013.
-
Abstract
- It is shown that a multigap resistive plate chamber made of commercial float glass is capable of sustaining high counting rates at an increased operating temperature. Two glass chambers were investigated on the test beamline of the U-70 accelerator at the Institute for High Energy Physics. The required radiation flux density at the detector was produced by means of radioactive sources. The time resolution of 80 ps or better was attained at a rate of ∼20 kHz/cm2 and an operating temperature of 45°C.
Details
- ISSN :
- 16083180 and 00204412
- Volume :
- 56
- Database :
- OpenAIRE
- Journal :
- Instruments and Experimental Techniques
- Accession number :