Abstract

Confirmation of pm rad scale emittances from the Advanced Photon Source Upgrade electron storage ring necessitates direct measurement of the electron beam size. In the present work, we motivate design choices for the X-ray beam size monitor shielding enclosure for the Advanced Photon Source Upgrade. Particular emphasis is given to outlining design choices from the perspectives of safety, overall project construction schedule and eventual beamline operations.<br />Proceedings of the 9th International Beam Instrumentation Conference, IBIC2020, Santos, Brazil