Back to Search
Start Over
PD inception characteristics in LN/sub 2//PP laminated paper composite insulation system for HTS cable
- Source :
- Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).
- Publication Year :
- 2004
- Publisher :
- IEEE, 2004.
-
Abstract
- In this paper, we discussed partial discharge (PD) inception characteristics in liquid nitrogen (LN/sub 2/)/polypropylene (PP) laminated paper composite insulation system in terms of volume effect and V-t characteristics, both for PD inception strength (PDIE). Different kinds of butt gap condition were applied in the experiments, using parallel plane and coaxial cylindrical cable samples. Experimental results revealed that the volume effect on PDIE could be evaluated by the statistical stressed liquid volume (SSLV) taking account the discharge probability not only in the butt gap but also in the other thin layers between PP laminated papers. Furthermore, the indices n of V-t characteristics at PD inception were estimated to be 80/spl sim/100, irrespective of the butt gap condition.
Details
- Database :
- OpenAIRE
- Journal :
- Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417)
- Accession number :
- edsair.doi...........37d3e5d14c7b98aebd72f3c74e2b0899
- Full Text :
- https://doi.org/10.1109/icpadm.2003.1218634