Back to Search Start Over

Deposition of aerosol particles on rough surfaces inside a test chamber

Authors :
Lucie Džumbová
Pavla Dohányosová
Jiří Hemerka
Aleš Hruška
Lenka Kubincová
Jiří Smolík
Tareq Hussein
Source :
Building and Environment. 44:2056-2063
Publication Year :
2009
Publisher :
Elsevier BV, 2009.

Abstract

We investigated the deposition rate of aerosol particles (diameter between 0.03 and 5 μm) on rough surfaces of wallpapers, wall-plasters, and two types of carpets inside a test chamber. Compared to a smooth aluminum surface, the deposition rate of aerosol particles on the tested surfaces was up to 20 times depending on the surface roughness, mixing intensity, and particle size. A rough surface with a dimensionless surface roughness height k+ 1 μm) when k+

Details

ISSN :
03601323
Volume :
44
Database :
OpenAIRE
Journal :
Building and Environment
Accession number :
edsair.doi...........378324818b469d62b15b8dedaf81c6c0
Full Text :
https://doi.org/10.1016/j.buildenv.2009.02.009