Back to Search
Start Over
Percutaneous left atrial appendage occlusion: Effect of device positioning on outcome
- Source :
- Catheterization and Cardiovascular Interventions. 88:656-664
- Publication Year :
- 2016
- Publisher :
- Wiley, 2016.
-
Abstract
- OBJECTIVE The study in patients with percutaneous left atrial appendage (LAA) occlusion investigates clinical outcomes according to the position of the Amplatzer Cardiac Plug (ACP) disc. BACKGROUND The ACP consists of a disc and an anchoring lobe. The disc is meant to cover the ostium of the LAA, but frequently retracts partially or completely into the neck of the LAA. It is not known whether a retracted disc affects outcome. METHODS Outcomes of 169 consecutive patients (age 73.1 ± 10.4 years; 76% male) with successful LAA closure were analyzed according to the position of the ACP disc: group A had complete coverage of the LAA ostium; in group B the disc prolapsed partially or completely into the LAA-neck. Transesophageal echocardiography was performed 1-6 months after ACP implantation. The safety endpoint was the composite of clinically significant pericardial effusion, device embolization, procedure-related stroke/transient ischemic attack (TIA), major bleeding, or device thrombus. The efficacy endpoint was the composite of death, neurological events (ischemic and hemorrhagic stroke, TIA), or systemic embolism during follow-up. RESULTS Group A comprised 76 patients (age 73.0 ± 9.9 years; 74% male) and group B 93 patients (age 73.3 ± 10.9 years; 79% male). Mean CHA2 DS2 -Vasc score and HASBLED score were 4.2 ± 1.7 (group A 4.3 ± 1.6; group B 4.2 ± 1.8) and 2.9 ± 1.1 (group A 2.9 ± 1.0; group B 3.0 ± 1.2), respectively. Mean follow-up of the study population was 13.0 ± 10.4 months. Overall, the composite safety and efficacy endpoints occurred in 20 (12%) and 6 patients (4%), respectively. There was no significant difference between groups A and B in the occurrence of the safety endpoint (13% vs. 11%, P = 0.64), or the efficacy endpoint (4% vs. 3%, P = 1.0). CONCLUSIONS No evidence for a difference in the occurrence of the safety and efficacy endpoint was found between patients with complete vs. incomplete ACP disc coverage of the LAA ostium. The risk of repositioning attempts in case of incomplete coverage does not seem to be warranted. Current findings need further confirmation in a larger scale clinical trial.
- Subjects :
- medicine.medical_specialty
Percutaneous
business.industry
medicine.medical_treatment
General Medicine
030204 cardiovascular system & hematology
medicine.disease
Pericardial effusion
Left atrial appendage occlusion
Surgery
Clinical trial
03 medical and health sciences
Ostium
0302 clinical medicine
Occlusion
Medicine
Radiology, Nuclear Medicine and imaging
030212 general & internal medicine
Thrombus
Cardiology and Cardiovascular Medicine
business
Stroke
Subjects
Details
- ISSN :
- 15221946
- Volume :
- 88
- Database :
- OpenAIRE
- Journal :
- Catheterization and Cardiovascular Interventions
- Accession number :
- edsair.doi...........3355595ee5b45bf2f1a23c6c5c744b12