Back to Search Start Over

Performance Evaluation of R/C Beam-Column Joint According to Unbonded Rebar

Authors :
Woo Young Jung
Min Ho Kwon
Jae Hoon Jung
Source :
Journal of the Korea institute for structural maintenance and inspection. 15:201-211
Publication Year :
2011
Publisher :
Korea Institute for Structural Maintenance Inspection, 2011.

Abstract

Many reinforced concrete structures have been constructed at the offshore in Korea and those are exposed in environments for long period. Due to that, the reinforcement of the structure faces possibility of corrosion by the salt damage. Such corrosions are effects on the bond performance between concrete and reinforcing bar as well as the performance of the structure. In this study, the performance of RC structure has been investigated when the reinforcing bars are totally bonded and unbonded in the structure. Through the experimental tests and finite element analyses of beam-column joint with bond and unbonded reinforcing bar, the energy dissipation capacity, strength, and crack distribution are compared and discussed.

Details

ISSN :
22346937
Volume :
15
Database :
OpenAIRE
Journal :
Journal of the Korea institute for structural maintenance and inspection
Accession number :
edsair.doi...........332db6f321b95553c16103e6626ddf64
Full Text :
https://doi.org/10.11112/jksmi.2011.15.6.201