Abstract

Cyclic voltammetry and potentiostatic polarization have been applied to study electrochemical behavior and to determine corrosion resistance of nitinol, which surface was modified with silicon using plasma-immersion ion implantation, in 0.9 % NaCl solution and in artificial blood plasma. It was found out that continuous, and also homogeneous in composition thin Si-containing layers are resistant to corrosion damage at high positive potentials in artificial physiological solutions due to formation of stable passive films. Breakdown potential Eb of Si-modified NiTi depends on the character of silicon and Ni distribution at the alloy surface, Eb values amounted to 0.9–1.5 V (Ag/AgCl/KCl sat.) for the alloy samples with continuous Si-containing surface layers and with decreased Ni surface concentration.