Back to Search
Start Over
Operating parameters affecting the thermal performance of biomass boilers
- Source :
- August 2017. 16:453-461
- Publication Year :
- 2017
- Publisher :
- TAPPI, 2017.
-
Abstract
- Operating data of a bubbling fluidized bed (BFB) boiler and three stoker grate (SG) biomass boilers from different pulp mills were analyzed over a 2-year period. The results show that in all cases, the thermal perfor - mance decreases markedly from 5.5 to 4 lb steam/lb dry biomass as the feedstock moisture content increases from 40% to 60%. The BFB boiler had better thermal performance, although it operated in a higher moisture content range compared with the SG boilers. Multivariate analysis was also performed on one of the SG boilers to determine operating parameters that affect thermal performance. The results show that furnace temperature, oil flow rate, and induced draft fan current positively correlate with thermal performance, while the feedstock moisture content, total air flow, and excess oxygen (O 2 ) negatively correlate with thermal performance. This implies that when making mod - ifications to improve thermal performance, it is important to take into account correlations among various parame - ters. In some cases, one positively correlated parameter might cause an increase in a negatively correlated parame - ter. The net effect might be a decrease in thermal performance.