Back to Search Start Over

The right to comfort: A field study on adaptive thermal comfort in free-running primary schools in Chile

Authors :
Maureen Trebilcock
Rodrigo Figueroa-San Martin
Jaime Soto-Muñoz
Miguel Yañez
Source :
Building and Environment. 114:455-469
Publication Year :
2017
Publisher :
Elsevier BV, 2017.

Abstract

This paper presents the results of a field study on thermal comfort in school buildings in Chile, the aim of which was to determine the comfort temperature of primary school children. Results are given for twelve schools that are located in Santiago, a city with relatively low temperatures in winter and high temperatures in summer, and that are typically free-running, as they have neither a heating nor a cooling system. The methodology included measurements of thermal parameters complemented with questionnaires based on the adaptive comfort model and modified to be understood by 9–10 year-old students. The fieldwork was organised into two phases: winter (July–August) and spring (November–December), and in each phase students answered the questionnaire up to three times per day over a period of three to four days. The results show that indoor temperatures in the classrooms are extremely low during occupancy hours in winter and quite high in spring, but the students' thermal sensation votes show that they tend to adapt quite dramatically to this wide variation. Comfort temperature is significantly lower than that calculated from the adaptive comfort model as established for adults, with temperatures as low as 14.7 °C - 15.6 °C in winter and 22.5 °C – 23.1 °C in spring. Additionally, students from highly vulnerable schools voted for a lower comfort temperature in winter than those from less vulnerable realities, thereby implying that there is a strong relation between comfort temperature and the socio-economic background of school children in this context.

Details

ISSN :
03601323
Volume :
114
Database :
OpenAIRE
Journal :
Building and Environment
Accession number :
edsair.doi...........30867f8761e2d2006ffadc23db65d3b8
Full Text :
https://doi.org/10.1016/j.buildenv.2016.12.036