Back to Search
Start Over
Relationship Between Intravascular Ultrasound Guidance and Clinical Outcomes After Drug-Eluting Stents
- Source :
- Circulation: Cardiovascular Interventions. 11
- Publication Year :
- 2018
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2018.
-
Abstract
- Background In the large-scale ADAPT-DES study (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents), drug-eluting stent implantation with intravascular ultrasound (IVUS) guidance was associated with a reduction in 1-year rates of stent thrombosis, myocardial infarction (MI), and major adverse cardiac events (cardiac death, MI, or stent thrombosis) compared with angiography guidance alone. We assessed whether the benefits of IVUS guidance were maintained, reduced, or increased at 2 years. Methods and Results ADAPT-DES was a prospective, multicenter, nonrandomized all-comers study of 8582 consecutive patients at 11 US and German sites designed to determine the frequency, timing, and correlates of adverse events after drug-eluting stents. Propensity-adjusted multivariable analysis was performed to examine the impact of IVUS guidance on 2-year outcomes. IVUS guidance (n=3361; 39%) compared with angiography guidance (n=5221; 61%) was associated with reduced 2-year adjudicated rates of (1) major adverse cardiac events (cardiac death, MI, or stent thrombosis; 4.9% versus 7.5%; adjusted hazard ratio, 0.72; 95% CI, 0.59–0.89; P =0.003), (2) definite/probable stent thrombosis (0.55% versus 1.16%; adjusted hazard ratio, 0.40; 95% CI, 0.22–0.73; P =0.003), and (3) MI (3.5% versus 5.6%; adjusted hazard ratio, 0.65; 95% CI, 0.51–0.83; P =0.0006). By landmark analysis, IVUS guidance compared with angiography guidance was also associated with significantly reduced rates of major adverse cardiac events, MI, stent thrombosis, and clinically driven target lesion revascularization between 1 and 2 years after drug-eluting stent implantation. The number needed to treat with IVUS guidance to prevent 1 major adverse cardiac event was reduced from 64 (42–137) at 1 year to 41 (29–69) at 2 years. Conclusions In ADAPT-DES, the early improvement in event-free survival after drug-eluting stent implantation with IVUS guidance compared with angiography guidance was further increased with longer term follow-up to 2 years. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT00638794.
- Subjects :
- Drug
medicine.medical_specialty
medicine.diagnostic_test
business.industry
media_common.quotation_subject
Follow up studies
030204 cardiovascular system & hematology
03 medical and health sciences
0302 clinical medicine
Intravascular ultrasound
Angiography
medicine
Stent implantation
030212 general & internal medicine
Radiology
Cardiology and Cardiovascular Medicine
business
media_common
Subjects
Details
- ISSN :
- 19417632 and 19417640
- Volume :
- 11
- Database :
- OpenAIRE
- Journal :
- Circulation: Cardiovascular Interventions
- Accession number :
- edsair.doi...........2ff47cb5f67a403da712829229f2c261
- Full Text :
- https://doi.org/10.1161/circinterventions.117.006243