Full-scale dynamic testing of response-controlled buildings and their components: concepts, methods, and findings
- Source :
- Earthquake Engineering and Engineering Vibration. 13:167-181
- Publication Year :
- 2014
- Publisher :
- Springer Science and Business Media LLC, 2014.
-
Abstract
- A series of shake-table tests was conducted by inserting and replacing 4 different types of dampers, or by removing them in a full-scale 5-story steel frame building. The objective is to validate response-control technologies that are increasingly adopted for major Japanese buildings without being attested to-date by a major earthquake. Test results are briefly described, and good performance of the dampers and frame demonstrated. The concepts of the full-scale building tests and various contributions are discussed. The difficulty associated with full-scale dynamic testing is explained.
- Subjects :
- Engineering
Viscous damper
business.industry
Mechanical Engineering
Frame (networking)
Full scale
Building and Construction
Structural engineering
Geotechnical Engineering and Engineering Geology
Damper
Steel frame
2008 California earthquake study
business
Civil and Structural Engineering
Dynamic testing
Subjects
Details
- ISSN :
- 1993503X and 16713664
- Volume :
- 13
- Database :
- OpenAIRE
- Journal :
- Earthquake Engineering and Engineering Vibration
- Accession number :
- edsair.doi...........2d8a606f4644cf65bad47ef0131f0d65