Abstract

Objectives The analytical sensitivity of high-sensitivity cardiac troponin T (hsTnT) assays has enabled rapid myocardial infarction rule-out algorithms for emergency department (ED) presentations. Few studies have analyzed the real-world impact of hsTnT algorithms on outcomes and operations. Methods Comparison of ED length of stay (LOS) and 30-day outcomes (return to ED, inpatient admission, and mortality) for patients presenting with chest pain during 2 separate 208-day periods using a 0/1-hour hsTnT-enabled algorithm or fourth-generation TnT. Results Discharge, 30-day readmission, and 30-day mortality rates were not significantly different with fourth-generation TnT vs hsTnT. Thirty-day return rates were significantly decreased with hsTnT (17.4% vs 14.9%; P Conclusions Implementation of the hsTnT algorithm was associated with decreased 30-day return rates and decreased ED LOS for a subset of patients, despite incomplete adoption of the 0/1-hour algorithm.