Back to Search
Start Over
A Transducer for the Direct Measurement of Rates of Lethality during Thermal Processing of Foods
- Source :
- Journal of Food Science. 50:223-225
- Publication Year :
- 2006
- Publisher :
- Wiley, 2006.
-
Abstract
- A transducer to directly measure lethality rates during thermal processing was designed and tested. The transducer consisted of a double-legged thermocouple, thermocouple conditioner, and an antilog amplifier. Lethality rates measured real-time during thermal process experiments compared well with those calculated after-wards. A microcomputer data acquisition system was designed to evaluate this transducer. This data system was a general purpose system and can be easily modified to meet the data recording needs of similar experiments and routine processing operations.
Details
- ISSN :
- 17503841 and 00221147
- Volume :
- 50
- Database :
- OpenAIRE
- Journal :
- Journal of Food Science
- Accession number :
- edsair.doi...........2d6944c35a83db6f15b32e42f61c0d4d
- Full Text :
- https://doi.org/10.1111/j.1365-2621.1985.tb13314.x