Fast nanoscale modification of Ag(111) using a scanning tunneling microscope
- Source :
- Applied Physics Letters. 58:702-704
- Publication Year :
- 1991
- Publisher :
- AIP Publishing, 1991.
-
Abstract
- Epitaxial Ag(111) films have been grown on mica. They exhibit flat terraces of a few 100 nm diameter, suitable for nanoscale modification with the scanning tunneling microscope (STM). Under ambient conditions, surface modifications of a few nanometers diameter were produced by raising the bias from below 1 V to a bias between 3 and 7 V for less than 50 ns. The steady‐state current could be limited to 2 pA. This means that the modification is initiated while only a few electrons pass the tunneling junction, indicating that it is not a current effect. At positive sample bias, usually holes are formed, while at negative bias hillocks occur. In the case of hole formation, the current does not change significantly on a time scale of 10 μs. When hillocks are formed, the current may rise after the application of the voltage pulse. It was limited to 4 nA by the external circuitry and remains saturated until the tip is withdrawn on a time scale of milliseconds, i.e., the characteristic for the feedback loop contro...
Details
- ISSN :
- 10773118 and 00036951
- Volume :
- 58
- Database :
- OpenAIRE
- Journal :
- Applied Physics Letters
- Accession number :
- edsair.doi...........28e9dfa378c05f138f768d7c83673ebf
- Full Text :
- https://doi.org/10.1063/1.104520