Back to Search Start Over

Traceability of the 10-kΩ standard at IEN

Authors :
C. Cassiago
Roberto Cerri
G. Boella
Andrea Sosso
Pier Paolo Capra
G.M. Reedtz
Source :
IEEE Transactions on Instrumentation and Measurement. 50:245-248
Publication Year :
2001
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2001.

Abstract

The traditional scaling method used at the Istituto Elettrotecnico Nazionale (IEN) for the calibration of the 10-k/spl Omega/ standard is compared with more straightforward techniques: one based on the linearity of a DVM and the other on a commercial current comparator bridge. For the three methods, the measurement results and the uncertainty budgets are reported. The agreement is better than 1/spl times/10/sup -7/.

Details

ISSN :
00189456
Volume :
50
Database :
OpenAIRE
Journal :
IEEE Transactions on Instrumentation and Measurement
Accession number :