Back to Search Start Over

Study of influence of wind pressure and rain conditions in rain screen walls

Authors :
Joaquín Fernández Madrid
Source :
Structural Survey. 28:46-52
Publication Year :
2010
Publisher :
Emerald, 2010.

Abstract

PurposeThe purpose of this paper is to design and develop a model for testing watertightness of rainscreen walls.Design/methodology/approachA test model was developed to determine the time to achieve equalisation and tightness rate of the rainscreen under investigation. Other tests include the distribution of wind loads to each rain screen layer, with the amount of water infiltrating into the cavity and the tightness rates.FindingsIt is found that the cavity must be compartmentalized, separating zones with different pressures. Vertically, corners and lateral stripes, 2 or 3m wide, must necessarily be compartmentalized. Horizontally, it is very convenient to compartmentalize the cavities of each floor, or at least every two floors (maximum 6m). When a cavity is not compartmentalized and tight, there will be air currents moving inside the cavity, and therefore the amount of infiltrated water through vents and joints will increase.Originality/valueThe paper demonstrates its value by developing a model to investigate the watertightness of rainscreen walls.

Details

ISSN :
0263080X
Volume :
28
Database :
OpenAIRE
Journal :
Structural Survey
Accession number :
edsair.doi...........26997c601daec5e902bb61605523a07c
Full Text :
https://doi.org/10.1108/02630801011040851