Back to Search
Start Over
The Dependence of Transport AC Loss on Temperature and DC Parallel Magnetic Field in an Eight-Strand YBCO Roebel Cable
- Source :
- IEEE Transactions on Applied Superconductivity. 23:5402604-5402604
- Publication Year :
- 2013
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2013.
-
Abstract
- We measure transport ac losses in an 8/2 (eight 2-mm-wide strands) YBCO Roebel cable at 77 and 65 K without dc parallel magnetic field, and at 77 K under dc parallel magnetic fields of 0-1.5 T. The transport ac loss in the Roebel cable scales with temperature and dc parallel magnetic field as the square of the cable's critical current.
- Subjects :
- Materials science
High-temperature superconductivity
Nuclear magnetic resonance
Condensed matter physics
law
Measure (physics)
Critical current
Electrical and Electronic Engineering
Condensed Matter Physics
Square (algebra)
Electronic, Optical and Magnetic Materials
law.invention
Magnetic field
Subjects
Details
- ISSN :
- 15582515 and 10518223
- Volume :
- 23
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Applied Superconductivity
- Accession number :
- edsair.doi...........25bcef1b17266580ec5bffa746cf33e2
- Full Text :
- https://doi.org/10.1109/tasc.2013.2240559