Back to Search
Start Over
Seismic response control tests and simulations by fuzzy optimal logic of building structures
- Source :
- Engineering Structures. 20:164-175
- Publication Year :
- 1998
- Publisher :
- Elsevier BV, 1998.
-
Abstract
- This paper outlines shaking table tests and their results for an active seismic response control system that uses fuzzy optimal logic (FOL). The test results confirmed the validity of the vibration control effect of this seismic response control system. The results of this study lead to two conclusions, that the effectiveness of this FOL control system can be increased by modifying the membership function, and that the results of seismic response control tests can be qualitatively evaluated by simple simulation methods.
Details
- ISSN :
- 01410296
- Volume :
- 20
- Database :
- OpenAIRE
- Journal :
- Engineering Structures
- Accession number :
- edsair.doi...........2586cfcafaa0bba789da1822949422f4
- Full Text :
- https://doi.org/10.1016/s0141-0296(97)00075-8