Back to Search
Start Over
Optimization of Room-Temperature Continuous-Wave Cr4+: Y AG Lasers: Experiment and Modeling
- Source :
- Advanced Solid State Lasers.
- Publication Year :
- 2000
- Publisher :
- Optica Publishing Group, 2000.
-
Abstract
- Experimental and numerical methods were employed to investigate the influence of thermal effects in room-temperature continuous-wave Cr4+:YAG lasers. Pump saturation, laser threshold, and laser efficiency data were first analyzed by accounting for the temperature dependence of the fluorescence lifetime, pump-induced heating in the gain medium, excited-state absorption at the lasing wavelength, and saturation effects. Best-fit values of the absorption, emission, and excited-state absorption cross sections were determined to be 11.2×10−19 cm2, 0.47×10−19 cm2, and 0.093×10−19 cm2, respectively. Based on the best-fit cross-section values, numerical calculations show that the optimum crystal length and absorption coefficient are 2 cm and 0.56 cm−1, respectively.
Details
- Database :
- OpenAIRE
- Journal :
- Advanced Solid State Lasers
- Accession number :
- edsair.doi...........24cf2f2e74adeaab7c183ce62a2f0237
- Full Text :
- https://doi.org/10.1364/assl.2000.tub10