Back to Search
Start Over
F-P Interferometer for Low Liquid Velocity Measurement with Non-contact and High Sensitivity
- Source :
- 2018 Asia Communications and Photonics Conference (ACP).
- Publication Year :
- 2018
- Publisher :
- IEEE, 2018.
-
Abstract
- A low liquid velocity sensor composed by a capillary vertically inserted in PTFE (Polytetrafluoroethylene) tube has been proposed and realized with high sensitivity. The achieved sensitivity to liquid velocity is 0.0016nm/(μL/min ).
Details
- Database :
- OpenAIRE
- Journal :
- 2018 Asia Communications and Photonics Conference (ACP)
- Accession number :
- edsair.doi...........22e00da4fc13b34683efeb805f361816
- Full Text :
- https://doi.org/10.1109/acp.2018.8596105