Back to Search Start Over

Experimental investigation of the connecting tube effect on a step displacer type two stage pulse tube refrigerator

Authors :
Yuzhe Lin
Zhaorui Guo
Zhimin Guo
Shaowei Zhu
Source :
Applied Thermal Engineering. 173:115229
Publication Year :
2020
Publisher :
Elsevier BV, 2020.

Abstract

Using the step displacer in two stage pulse tube refrigerator has already been proved as a sufficient way to improve the efficiency. In this article, an experimental setup has been manufactured. A no-load temperature of 16.9 K is achieved with a step displacer type gas-coupled pulse tube refrigerator filled with stainless steel mesh. The influence of the connecting tube between pulse tube hot end and displacer on the performance of the refrigerator is investigated. The experimental results show that the phase shifting ability can be adjusted by the connecting tube. The performance of the refrigerator can be optimized by this method. For different rod diameters, there is an optimum connecting tube ratio to get the lowest temperature.

Details

ISSN :
13594311
Volume :
173
Database :
OpenAIRE
Journal :
Applied Thermal Engineering
Accession number :
edsair.doi...........1c18d853ea9732eda8f93061acd5694a
Full Text :
https://doi.org/10.1016/j.applthermaleng.2020.115229