Back to Search Start Over

Experimental Research of Heat Transfer Enhancement of the Tube with Disturbed Flow Components Plug-In

Authors :
Rui Qu
Chang Fa Ji
Guo Xin He
Source :
Advanced Materials Research. :479-484
Publication Year :
2014
Publisher :
Trans Tech Publications, Ltd., 2014.

Abstract

Based on Field Synergy Principle and orthogonal experiment design, nine arranged metal-wire inserts(that is high porosity porous inserts) is determined to experiment. The results showed that heat transfer performance of the pipe that metal-wire inserts is rooted at the core region of pipe is better than the pipe that metal-wire inserts is rooted at the edge region of pipe., location and curve radian can impact heat exchange significantly. Under the given experimental condition, the heat transfer quantity increased by 120 - 520%, overall heat transfer coefficient increased by 126 - 610%. Through enhancing heat transfer performance evaluation criterion (PEC) comprehensive evaluation, it is concluded that when the Reynolds number Re changes in 338 ~ 6931, the PEC value of 0.89 ~ 5.97.The calculation formula of the drag coefficient is obtained by regression analysis.

Details

ISSN :
16628985
Database :
OpenAIRE
Journal :
Advanced Materials Research
Accession number :
edsair.doi...........1b2d058eb4aadbd36056e9bf399d740c
Full Text :
https://doi.org/10.4028/www.scientific.net/amr.960-961.479