Transient Hydraulic Performance and Numerical Simulation of a Centrifugal Pump with an Open Impeller during Shutting Down
- Source :
- Open Journal of Fluid Dynamics. :348-353
- Publication Year :
- 2012
- Publisher :
- Scientific Research Publishing, Inc., 2012.
-
Abstract
- In this paper, the transient behavior of a low specific speed centrifugal pump with straight blades during shutting down is studied through the experimental test, theoretical calculation, and numerical simulation. The variations of the rota- tional speed, flow rate, and head with time are obtained in experiment. Based on the experimental results of the rota- tional speed and flow rate, the additional theoretical heads are quantitatively calculated and analyzed. The experimental results of the rotational speed and flow rate are worked as the boundary conditions to accurately accomplish the nu- merical simulation of the transient flow during shutting down. The experimental results show that the decrease history of the flow rate evidently lags behind that of the rotational speed, while the rotational speed slightly lags behind the head. Theoretical analysis shows that there exists a clear negative head impact phenomenon in the process of stopping. The transient behavior of the centrifugal pump with straight blades mainly comes from the rotation deceleration of im- peller, and has nothing to do with the fluid deceleration. The numerical simulations show that a large area backflow can be seen when the rotational speed decreases to zero due to the flowing inertia. In conclusion, the numerical simulation of the flow field is in good agreement with the internal flow theory of centrifugal pumps.
Details
- ISSN :
- 21653860 and 21653852
- Database :
- OpenAIRE
- Journal :
- Open Journal of Fluid Dynamics
- Accession number :
- edsair.doi...........19eabc93dc385c8a705f13941c7feb2b
- Full Text :
- https://doi.org/10.4236/ojfd.2012.24a044