Back to Search
Start Over
Clinical safety and wear resistance of the phospholipid polymer-grafted highly cross-linked polyethylene liner
- Source :
- Journal of Orthopaedic Research. 35:2007-2016
- Publication Year :
- 2016
- Publisher :
- Wiley, 2016.
-
Abstract
- To reduce the production of wear particles and subsequent aseptic loosening, we created a human articular cartilage-mimicked surface for a highly cross-linked polyethylene liner, whose surface grafted layer consisted of a biocompatible phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine). Although our previous in vitro findings showed that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted particles were biologically inert and caused no subsequent bone resorptive responses, and poly(2-methacryloyloxyethyl phosphorylcholine) grafting markedly decreased wear in hip joint simulator tests, the clinical safety, and in vivo wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners remained open to question. Therefore, in the present study, we evaluated clinical and radiographic outcomes of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners 5 years subsequent to total hip replacement in 68 consecutive patients. No reoperation was required for any reason, and no adverse events were associated with the implanted liners. The average Harris Hip Score increased from 38.6 preoperatively to 96.5 5 years postoperatively, and health-related quality of life, as indicated by the Short Form 36 Health Survey, improved. Radiographic analyses showed no periprosthetic osteolysis or implant migration. Between 1 and 5 years postoperatively, the mean steady-state wear rate was 0.002 mm/year, which represented a marked reduction relative to other highly cross-linked polyethylene liners, and appeared to be unaffected by patient-related or surgical factors. Although longer follow up is required, poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners improved mid-term clinical outcomes. The clinical safety and wear-resistance results are encouraging with respect to the improvement of long-term clinical outcomes with poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2007–2016, 2017.
- Subjects :
- musculoskeletal diseases
chemistry.chemical_classification
030222 orthopedics
medicine.medical_specialty
Cross-linked polyethylene
Joint replacement
Phosphorylcholine
business.industry
medicine.medical_treatment
02 engineering and technology
Polymer
Polyethylene
021001 nanoscience & nanotechnology
Arthroplasty
Surgery
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
chemistry
Harris Hip Score
medicine
Orthopedics and Sports Medicine
Implant
0210 nano-technology
business
Subjects
Details
- ISSN :
- 07360266
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Journal of Orthopaedic Research
- Accession number :
- edsair.doi...........195e04637d3ab7940a06fd1e8738d492
- Full Text :
- https://doi.org/10.1002/jor.23473